400G QSFP-DD DR4

400G QSFP-DD DR4

400GBASE-DR4 QSFP-DD PAM4 Silicon Photonics Transceiver Module What is 400G-DR4 This product is a 400Gb/s QSFP-DD optical module designed for 0.5Km optical communication applications. The module converts 8 channels of 50Gb/s (PAM4) electrical input data to 4 channels of parallel optical signals,...

  • Product Introduction

 

400G QSFP-DD DR4 Optical Transceiver

 

High-performance 400GBASE-DR4 module with Silicon Photonics technology. Supports 500m SMF transmission and 4×100G breakout capability. Ideal for hyperscale data centers and AI/GPU cluster interconnects.

  • 425G Maximum Speed
  • 500M Maximum Distance
  • <10W Typical Power Consumption

 

 

400G QSFP-DD DR4 Optical Transceiver

 

Product Highlights

 

Industry-leading technology for high-speed data center connectivity

400G QSFP-DD DR4 DSP Chip

High-Performance DSP Chip

Built-in Broadcom 7nm DSP with typical power consumption under 10W, significantly reducing data center energy costs.

Silicon Photonics Technology

Silicon Photonics Technology

Advanced 300mm wafer CMOS process with >85% yield rate. Higher integration density and lower manufacturing costs.

4×100G Breakout Support

4×100G Breakout Support

Flexible breakout to 4×100G-DR interfaces or 2×200G-DR2 for gradual network upgrades and investment protection.

500m SMF Transmission

500m SMF Transmission

Meets intra-data center interconnect requirements. Perfect for Spine-Leaf architecture high-speed connections.

Full Standards Compliance

Full Standards Compliance

Compliant with IEEE 802.3bs, QSFP-DD MSA CMIS Rev4.1, OIF CEI-56G-VSR-PAM4, and 100G Lambda MSA.

Multi-Brand Compatibility

Multi-Brand Compatibility

Tested and verified compatible with Cisco, Arista, Juniper, Dell, Huawei, HPE, NVIDIA/Mellanox equipment.

 

Key Specifications

425Gbps
Max Data Rate
(4×106.25Gb/s PAM4)
500m
Transmission
Distance (SMF)
<10W
Power
Consumption
MPO-12
APC
Connector

 

Specifications

Part Number QDD-DR4-400G Vendor Name FB-LINK
Form Factor QSFP-DD Max Data Rate 425Gbps(4x106.25Gb/s)
Wavelength 1310nm Max Cable Distance 500m
Connector MTP/MPO-12 Media SMF
Transmitter Type DFB Receiver Type PIN
Tx Power -2.9~4.0dBm Rx Power -5.9~4.0dBm
Power Consumption ≤10W Extinction Ratio 3.5dB
Powerbudget 3dB Modulation 8x50G PAM4

 

 

Compatibility & Platform Support

FB-LINK 400G QSFP-DD DR4 modules are fully tested and verified compatible with major networking platforms:

 

Certified Switch Compatibility

Brand Compatible Models Min. Software Version
Cisco Nexus 9316D-GX, 9332D-GX, 93600CD-GX, 9408, 9500 w/400G line cards, Catalyst 9500 NX-OS 10.2(1)+, IOS-XE 17.x+
Arista 7800R3-36P-LC, 7800R3-36D-LC, 7500R3-24P-LC, 7280R3-24, 7280CR3-32P4 EOS 4.25.x+
Juniper QFX5220-32CD, QFX5220-128C, QFX5230, QFX5240, PTX10001-36MR, PTX10003, PTX10008 Junos Evolved 21.2R1+
Dell EMC PowerSwitch S5448F-ON, Z9332F-ON, Z9432F-ON, Z9664F-ON OS10 10.5+
HPE/Aruba CX 9300-32D, CX 9300S, CX 10000 AOS-CX 10.11+
Huawei CloudEngine CE9860-4C-EI/HI, CE8800, CE6800 V200R020C00+
NVIDIA/Mellanox Spectrum-3 SN4700, Spectrum-4 SN5400/5600/5800 Cumulus/SONiC
Edge-Core AS9716-32D, AS9726-32DB, AS9737-32DB ONIE/SONiC

 

NIC Interoperability

NIC Model Interface Connection Method
NVIDIA ConnectX-7 (OSFP) OSFP 400G Optical interop (same DR4 standard)
Broadcom BCM57608 QSFP112 400G Direct optical interop
Intel E810 (100GbE) QSFP28 100G 4×100G Breakout

 

Breakout Configurations

Configuration Far-end Module Max Distance Cable Required
4×100G-DR1 QSFP28 100G-DR 500m MPO-12 to 4×LC Duplex
4×100G-FR1 QSFP28 100G-FR 500m* MPO-12 to 4×LC Duplex
2×200G-DR2 QSFP56-DD 200G-DR2 500m MPO-12 trunk

 

*Distance limited by shorter-reach module

 

QSFP-DD compatibility

 
 

FB-LINK develops and produces 100G QSFP28, 200G QSFP56, 400G QSFP112, 400G OSFP, and 800G OSFP.

ARISTA
CISCO
H3C
HUAWEI
ZTE
Alcatel-Lucent
JUNIPER
Mikrotik
Intel
HP

Tested in Host Devices for Proven Interoperability

Every unit is quality tested for compatibility in the targeted switch environment, which guarantees flawless operations.

Tested in Host Devices for Proven Interoperability

 

Application Scenarios

From hyperscale data centers to enterprise campus, meeting diverse high-speed interconnect needs.

Hyperscale Data Center Interconnect

High-speed interconnects between Spine switches in Spine-Leaf architecture. Supports 36-port/1U high-density deployment. Typical distance coverage: 100m-500m. Ideal for cloud service providers building massive east-west bandwidth infrastructure.

01

AI & GPU Cluster Networking

Interconnects for NVIDIA DGX H100/H200/B200, AMD MI300 AI servers. Supports NVIDIA Quantum-2 InfiniBand (NDR 400G) and Spectrum-4 Ethernet switches. Ultra-low latency for distributed training frameworks. Scales from 8-GPU nodes to 10,000+ GPU supercomputers.

02

100G to 400G Network Upgrade

Leverage breakout capability for investment-protected upgrades. Install 400G DR4 in new spine switch, connect to existing 100G QSFP28 DR modules via breakout cable, then upgrade 100G sites to 400G as needed. No forklift upgrade required.

03

Enterprise Campus Backbone

Connect campus buildings with high-speed backbone. 500m reach covers most campus distances. Lower fiber count than FR4 (parallel vs. CWDM). Core switch to aggregation layer high-speed interconnect. Future-proof infrastructure for 10+ years.

04

 

Breakout Connectivity

Flexible Breakout Configurations

The 400G QSFP-DD DR4 supports multiple breakout configurations for maximum deployment flexibility:

 

4×100G-DR1: Far-end QSFP28 100G-DR | Max 500m | MPO-12 to 4×LC Duplex cable

4×100G-FR1: Far-end QSFP28 100G-FR | Max 500m* | MPO-12 to 4×LC Duplex cable

2×200G-DR2: Far-end QSFP56-DD 200G-DR2 | Max 500m | MPO-12 trunk cable

 

*Distance limited by shorter-reach module

Recommended Cable: MTP/MPO-12 to 4×LC Duplex breakout patch cord

 

Free Custom EEPROM Coding for Seamless Integration

 

We provide free custom EEPROM coding to ensure seamless compatibility with your network equipment:

 

Cisco-specific coding: QDD-400G-DR4-S

Arista-specific coding: QDD-400G-DR4-AR

Juniper-specific coding: QDD-400G-DR4

Dell/HPE/Huawei-specific coding: Available on request

 

Turnaround Time: 1-2 business days additional

 

Request Custom Coding

 

Industry-Recognized Certifications

ISA,High-tech Enterprise Certificate,CIRCLE Certification,SGS Certification,ISO 9001:2015,IAF

ROHS,ISO 14001,ISO 9001,CE

ISO 4001,ISO 9001,ISA,CIRCLE

 FAQ About 400G QSFP-DD DR4 Optical Transceiver

Q: Will this module work with my Cisco or Arista switch?

A: Yes. It works out-of-the-box with most enterprise switches. To eliminate "unsupported transceiver" warnings, we offer free EEPROM coding tailored for Cisco, Arista, Juniper, and other platforms-just let us know your switch model when ordering.

Q: How does pricing compare to brand-name alternatives?

A: Expect 60-80% savings versus OEM-branded equivalents. We use identical Silicon Photonics technology and Broadcom DSP chips-the cost difference comes from eliminating brand markup, not cutting quality.

Q: What's covered under warranty?

A: 3-year coverage for defects and performance issues, plus a 30-day money-back guarantee. Extended 5-year options available for enterprise deployments.

Q: Is there a minimum order? How fast can I get it?

A: No MOQ-order even a single unit for evaluation. In-stock items ship within 1-3 business days. Volume discounts kick in at 100+ units.

Q: DR4 vs FR4 vs LR4-which do I need?

A: It depends on distance. DR4 covers up to 500m using 4 parallel fibers-best for intra-datacenter links. FR4 reaches 2km on 2 fibers via wavelength multiplexing. LR4 extends to 10km for campus backbones. For most rack-to-rack or row-to-row connections, DR4 offers the lowest cost and power draw.

Q: Can I connect this to my existing 100G equipment?

A: Absolutely. Use breakout mode to split one 400G port into four 100G connections via an MPO-to-LC cable. This lets you upgrade spine switches to 400G while keeping leaf switches at 100G-no forklift upgrade required.

Q: What makes QSFP-DD different from QSFP28?

A: Double the electrical lanes-8 versus 4-enabling 400G in a similar footprint. The connector is backward compatible, so you can still use QSFP28 modules in DD ports at lower speeds.

Q: Why PAM4 instead of traditional NRZ signaling?

A: PAM4 packs 2 bits per symbol (vs 1 bit in NRZ), doubling throughput without doubling the signaling frequency. This keeps electronics affordable while hitting 400G speeds. The built-in 7nm DSP handles the extra signal processing at under 10W.

Q: How do I install it?

A: Hot-swap friendly-no downtime needed. Clean the fiber ends, slide the module in until it clicks, connect your MPO-12 cable, done. Auto-negotiation handles the rest. For breakout mode, configure the port as "4x100G" in your switch CLI.

Q: Link errors or weak signal-what should I check?

A: Start with the basics: dirty connectors (clean with lint-free wipes), wrong fiber type (must be single-mode), or excessive bend radius. Verify the link is under 500m and your switch firmware meets the minimum version in our compatibility list. Check Tx/Rx power via CLI-abnormal readings point to cable or connector issues.

 

Hot Tags: Optical Transceivers

Send Inquiry

(0/10)

clearall