video

400G QSFP-DD CWDM4 10KM Optical Transceiver Module

High-performance 400Gb/s optical transceiver with 4-wavelength CWDM technology for metro network connectivity, data center interconnect (DCI), and enterprise backbone applications. The only 400G QSFP-DD solution combining 10km reach with cost-effective LC duplex interface.

  • Product Introduction

400G QSFP-DD CWDM4 10KM Optical Transceiver Module

FB-LINK has launched a cost-effective 400G QSFP-DD optical transceiver module suitable for long-distance end-user communication. The 400G QSFP-DD CWDM4 10KM uses a dual-fiber LC single-mode interface and utilizes four CWDM wavelengths (1271/1291/1311/1331nm) for transmission, meeting low power consumption requirements (≤12W). It complies with the 400G-LR4-10 MSA standard and supports 10km transmission.

Using CWDM wavelength

4*100G
1271nm 1291nm 1311nm 1331nm

Applicable Scenarios

Data Center Interconnect (DCI): Interconnection of data centers within a campus or metropolitan area network
Metropolitan Area Network: Metropolitan area access/aggregation layer transmission

400G QSFP-DD CWDM4 10KM Optical Transceiver Module

≤12W

Power consumption

Duplex_LC

Interface

400G-LR4-10 MSA

Meets standards

10KM

Transmission Distance

 

What Makes This 400G CWDM4 Module Different

 

Purpose-built for metro networks and DCI applications where extended reach and fiber efficiency are critical requirements

 

 

 

 

CWDM Wavelength Multiplexing

Transmits 4×100G channels (1271/1291/1311/1331nm) on a single fiber pair using Coarse Wavelength Division Multiplexing-unlike parallel optics that need 8-12 separate fibers.

 

  • CWDM Channels
  • 75% Fiber Reduction

10KM Metro-Scale Reach

Extends 400G connectivity to 10 kilometers-20× farther than DR4 (500m) and 5× farther than FR4 (2km). Ideal for campus backbone, building-to-building links, and metro DCI.

 

  • 10km Max Distance
  • 20× vs DR4 Reach

Standard LC Duplex Interface

Uses widely-deployed LC duplex connectors-not expensive MPO/MTP. Leverage existing single-mode fiber plant without connector upgrades or specialized patch cables.

 

  • 2 Fiber Strands
  • 50% Cable Cost Savings
4-Channel CWDM Wavelength Architecture

Why CWDM4 Technology for 400G Metro Networks

 

Coarse Wavelength Division Multiplexing (CWDM) enables 400G transmission over standard single-mode fiber infrastructure without the fiber count penalty of parallel optics solutions.

 

Fiber Infrastructure Efficiency
Use existing 2-fiber SMF runs instead of 8-12 fiber parallel solutions-critical for metro networks where fiber is expensive or limited

 

Cooled EML Laser Technology
Temperature-stabilized Electro-absorption Modulated Lasers ensure wavelength accuracy and long-term signal stability across operating conditions

 

Built-in MUX/DEMUX
Integrated optical multiplexer/demultiplexer combines and separates 4 wavelength channels-no external passive components required

 

100G Lambda MSA Compliant
Full compliance with 400G-LR4-10 MSA specification ensures multi-vendor interoperability and future upgrade path

400G QSFP-DD Module Comparison: CWDM4 vs DR4 vs FR4

Choose the right 400G transceiver for your specific deployment scenario

 

Parameter CWDM4 10KM (This Product) DR4 500m FR4 2KM
Transmission Distance 10km Best 500m 2km
Optical Technology 4λ CWDM MUX (1271-1331nm) 4× Parallel 1310nm 4λ CWDM MUX (1271-1331nm)
Connector Type LC Duplex Most Common MPO-12 LC Duplex
Fiber Count 2 fibers Lowest 8 fibers 2 fibers
Power Consumption ≤12W ≤10W Lowest ≤14W
Best Application Metro DCI, Campus Backbone, Enterprise WAN Intra-DC Spine-Leaf Inter-Building, Short DCI
Fiber Cost Impact Low (existing LC plant) High (MPO infrastructure) Low (existing LC plant)

 

Recommendation: Choose CWDM4 10KM for metro/campus networks requiring extended reach. Choose DR4 for high-density intra-DC links where 500m is sufficient. Choose FR4 for short inter-building connections under 2km.

400G QSFP-DD CWDM4 10KM Specifications

Complete technical parameters for system integration and network design

General Specifications

 
Form Factor OSFP-DD (Double Density)
Data Rate 4×100G (400Gb/s aggregate)
Wavelength 1271/1291/1311/1331nm (CWDM)
Transmission Distance Up to 10km
Connector Duplex LC
Fiber Type G.652 Single-Mode Fiber (SMF)
Modulation PAM4 (8×53.125Gb/s electrical)

Optical Characteristics

 

Transmitter Type Cooled EML (4-channel)
Receiver Type PIN Photodiode (4-channel)
Tx Power (per lane) -2.8 ~ 5.3 dBm
Rx Sensitivity -9.1 dBm (min)
Extinction Ratio ≥3.5 dB
Link Budget >6 dB

Electrical & Environmental

 

Power Consumption ≤12W (typical 10W)
Supply Voltage +3.3V single supply
Operating Temperature 0°C to +70°C (Commercial)
Storage Temperature -40°C to +85°C
Humidity 5% to 95% (non-condensing)

Standards & Compliance

 

MSA Compliance OSFP-DD MSA Rev 5.0+
Optical Standard 100G Lambda MSA 400G-LR4
Management CMIS 5.0 (DDM/DOM supported)
Safety IEC 60825-1 Class 1 Laser
EMC/RoHS CE, FCC Part 15, RoHS 3.0
Warranty 5 Years Standard

400G QSFP-DD CWDM4 Switch Compatibility

FB-LINK 400G QSFP-DD CWDM4 10KM modules are tested and verified compatible with leading networking platforms. We provide free custom EEPROM coding for seamless plug-and-play operation.

 

Vendor Compatible Platforms Minimum Software Part Number Coding
Cisco Nexus 9316D-GX, 9332D-GX, 93600CD-GX, 9408, 9500 series NX-OS 10.2(1)+ QDD-400G-LR4-S
Arista 7800R3, 7500R3, 7280R3, 7280CR3 series EOS 4.25.x+ QDD-400G-LR4
Juniper QFX5220, QFX5230, QFX5240, PTX10001/10003/10008 Junos Evolved 21.2R1+ QDD-400G-LR4
Huawei CloudEngine CE9860, CE8800, CE6800 series V200R020C00+ QSFP-DD-400G-LR4
H3C S12500X-AF, S9850 series Comware 7.x QSFP-DD-400G-LR4-H3C
Dell EMC PowerSwitch S5448F-ON, Z9332F-ON, Z9432F-ON OS10 10.5+ QSFP-DD-400G-LR4
ARISTA
CISCO
H3C
HUAWEI
JUNIPER

Why Choose FB-LINK for 400G Optical Transceivers

 


 

90% Same-Day Shipping

Extensive inventory of 400G QSFP-DD CWDM4 modules ready for immediate dispatch. Express shipping options worldwide.

 

 

Free Custom Coding

Complimentary EEPROM programming for Cisco, Arista, Juniper, and all major switch vendors. 24-48 hour turnaround.

 

 

5-Year Warranty

Industry-leading warranty coverage with advance RMA replacement. Free lifetime technical support included.

 

 

Global Support Network

5 regional service centers supporting 300,000+ enterprise customers across 200+ countries. 24/7 technical assistance.

 

 

FAQ

Q: What is the difference between CWDM4 and LR4 for 400G transceivers?

A: CWDM4 and LR4 often refer to the same optical technology for 400G-both use 4 CWDM wavelengths (1271/1291/1311/1331nm) for 10km transmission. The terms are sometimes used interchangeably; our 400G QSFP-DD CWDM4 10KM module complies with the 100G Lambda MSA 400G-LR4-10 specification.

Q: Can I use 400G CWDM4 modules with existing LC fiber infrastructure?

A: Yes, 400G QSFP-DD CWDM4 transceivers use standard LC duplex connectors and work with existing G.652 single-mode fiber runs. No special fiber types or connector upgrades are required-you can leverage your current 10G/40G/100G LC fiber plant.

Q: What is the power consumption advantage of CWDM4 vs coherent 400G?

A: Our 400G QSFP-DD CWDM4 consumes ≤12W versus 15-24W for coherent 400G ZR/ZR+ modules. For metro DCI under 10km, CWDM4 provides significant power and cost savings while delivering the required reach-coherent technology is better suited for 80km+ applications.

Q: Is FEC required for 400G CWDM4 links?

A: Yes, 400G CWDM4/LR4 links require host-side Forward Error Correction (FEC)-typically KP4 RS(544,514) FEC performed by the switch ASIC. The module itself does not include built-in FEC; this is consistent with the IEEE 802.3bs and 100G Lambda MSA specifications.

Q: Can 400G CWDM4 interoperate with other 400G-LR4 modules?

A: Yes, FB-LINK 400G QSFP-DD CWDM4 modules are fully compliant with 100G Lambda MSA 400G-LR4 specification, ensuring interoperability with any MSA-compliant 400G-LR4 transceiver from other vendors including Cisco, Arista, Juniper, and third-party suppliers.

Q: What fiber cleaning requirements apply to 400G CWDM4?

A: PAM4 signaling at 400G is more sensitive to optical impairments than NRZ. We recommend cleaning all LC connectors with lint-free wipes and 99% IPA before installation. Use inspection scopes to verify cleanliness-contamination can cause BER degradation at extended distances.

 

Ready to Deploy 400G CWDM4 10KM Transceivers?

 

Contact FB-LINK for wholesale pricing, custom coding services, and technical consultation for your metro DCI or campus backbone project.

 

Contact now

 

Related 400G Optical Transceiver Products

Explore our complete 400G QSFP-DD portfolio for different reach requirements

400G QSFP-DD DR4

400G QSFP-DD DR4

500m | MPO-12 | 4×100G Parallel | ≤10W

400G OSFP SR4

400G OSFP SR4

100m MMF | MPO-12 | InfiniBand Compatible

DCI OTN Solutions

DCI OTN Solutions

100G-3.2T | Long-Haul Coherent | DWDM

Hot Tags: 400G QSFP-DD CWDM4 10KM Optical Transceiver Module, 400GBASE-LR4 transceiver, 400G optical module, CWDM4 optical transceiver, 400G metro transceiver, 400G DCI module, 400G QSFP-DD LC duplex, 400G SMF transceiver 10km, 400G CWDM wavelength module, 400G enterprise optical transceiver, 400G QSFP-DD Cisco compatible, 400G QSFP-DD Arista compatible, wholesale 400G transceiver, China 400G transceiver manufacturer

Previous: No Information
Next: 400G QSFP-DD DR4
Send Inquiry

(0/10)

clearall